<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Zeiss Cirrus HD-OCT 4000 Archives - MULTIHEALTH BEAUTY</title>
	<atom:link href="https://www.multihealthbeauty.com/product-tag/zeiss-cirrus-hd-oct-4000/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.multihealthbeauty.com/product-tag/zeiss-cirrus-hd-oct-4000/</link>
	<description>International Medical Laser</description>
	<lastBuildDate>Tue, 13 May 2025 15:04:25 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>

<image>
	<url>https://i0.wp.com/www.multihealthbeauty.com/wp-content/uploads/2024/06/logo-multi.png?fit=32%2C13&#038;ssl=1</url>
	<title>Zeiss Cirrus HD-OCT 4000 Archives - MULTIHEALTH BEAUTY</title>
	<link>https://www.multihealthbeauty.com/product-tag/zeiss-cirrus-hd-oct-4000/</link>
	<width>32</width>
	<height>32</height>
</image> 
<site xmlns="com-wordpress:feed-additions:1">193758880</site>	<item>
		<title>Zeiss Cirrus HD-OCT 4000 System</title>
		<link>https://www.multihealthbeauty.com/product/zeiss-cirrus-hd-oct-4000-system/</link>
					<comments>https://www.multihealthbeauty.com/product/zeiss-cirrus-hd-oct-4000-system/#respond</comments>
		
		<dc:creator><![CDATA[Multihealth Beauty]]></dc:creator>
		<pubDate>Mon, 10 May 2021 18:07:53 +0000</pubDate>
				<guid isPermaLink="false">https://www.multihealthbeauty.com/?post_type=product&#038;p=5736</guid>

					<description><![CDATA[<p>The proprietary Selective Pixel Profiling technology enhances anatomical features while reducing image noise.</p>
<p>Zeiss Cirrus HD-OCT 4000 System enables repeatable visualization of clinically relevant anatomy with exact correlation between the OCT scan and the fundus image. Comprehensive navigational tools ensure efficient and simple operation.</p>
<p>The post <a href="https://www.multihealthbeauty.com/product/zeiss-cirrus-hd-oct-4000-system/">Zeiss Cirrus HD-OCT 4000 System</a> appeared first on <a href="https://www.multihealthbeauty.com">MULTIHEALTH BEAUTY</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Zeiss Cirrus HD-OCT 4000 System</p>
<ul>
<li><span style="color: #202020;">Optics provide superior visualization of anatomical details across a wider range of patients.</span></li>
<li><span style="color: #202020;">Robust engineering with premium components ensures consistent precision performance.</span></li>
<li><span style="color: #202020;">Unique  layer maps and images highlight clinically relevant details for identification and monitoring of specific diseases – all at a glance.</span></li>
</ul>
<p><span style="color: #202020;">Zeiss Cirrus HD-OCT 4000 System delivers superior image data. The new Enhanced Raster Scan leverages this power to produce images with outstanding detail while maintaining patient throughput. The proprietary Selective Pixel Profiling technology enhances anatomical features while reducing image noise.</span></p>
<p><span style="color: #202020;">Zeiss Cirrus HD-OCT 4000 System enables repeatable visualization of clinically relevant anatomy with exact correlation between the OCT scan and the fundus image. Comprehensive navigational tools ensure efficient and simple operation.</span><b></b></p>
<p><b><span style="color: #202020;">Designed for efficiency</span></b></p>
<ul>
<li><span style="color: #202020;">Small footprint and integrated design are ideal for crowded or busy practice</span></li>
<li><span style="color: #202020;">90 degree <a href="https://www.google.com/url?sa=t&amp;rct=j&amp;q=&amp;esrc=s&amp;source=web&amp;cd=&amp;cad=rja&amp;uact=8&amp;ved=2ahUKEwigh_yn2r_wAhWEfn0KHd27A_QQFjAAegQIAxAD&amp;url=https://www.zeiss.com/content/dam/Meditec/us/download/certified-pre-owned-systems/CIRRUS%204000.pdf&amp;usg=AOvVaw2oXxnnOapycuw7LOndq-6B">orientation</a> facilitates observation of patient throughout exam</span></li>
<li><span style="color: #202020;">Advanced optics aid in the examination of patients with cataracts</span></li>
<li><span style="color: #202020;">Dilation is not required even for pupils as small as 2.5 mm</span></li>
<li><span style="color: #202020;">Mouse Driven Alignment<img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2122.png" alt="™" class="wp-smiley" style="height: 1em; max-height: 1em;" /> delivers superior image capture and analysis in just a few clicks, resulting in reduced chair time for the patient</span></li>
<li><span style="color: #202020;">Auto Patient Recall assures patient position and instrument setting are repeated from previous visit</span></li>
</ul>
<p><b><span style="color: #202020;">Technical data</span></b></p>
<p><span style="font-size: large;"><span style="color: #202020;">OCT Scanning<br />
</span></span></p>
<ul>
<li><span style="color: #202020;">Axial resolution: 5 μm (in tissue)</span></li>
<li><span style="color: #202020;">Transverse resolution: 15 μm (in tissue)</span></li>
<li><span style="color: #202020;">Scan speed: 27,000 A-scans per second</span></li>
<li><span style="color: #202020;">A-scan depth: 2.0 mm (in tissue), 1024 points</span></li>
<li><span style="color: #202020;">Optical source: superluminescent diode (SLD), 840 nm</span></li>
</ul>
<p><span style="color: #202020;">\Fundus Imaging</span></p>
<ul>
<li><span style="color: #202020;">Line scanning ophthalmoscope (LSO)</span></li>
<li><span style="color: #202020;">Live during scanning</span></li>
<li><span style="color: #202020;">Transverse resolution: 25 μ (in tissue)</span></li>
<li><span style="color: #202020;">Optical source: <a href="https://www.multihealthbeauty.com/product/zeiss-cirrus-hd-oct-4000-system/">superluminescent</a> diode (SLD), 750 nm</span></li>
<li><span style="color: #202020;">Field of view: 36° x 30°</span></li>
</ul>
<p><span style="color: #202020;">Scan Patterns</span></p>
<ul>
<li><span style="color: #202020;">Macular Cube 200 x 200 Combo: 200 horizontal scan lines comprised of 200 A-scans</span></li>
<li><span style="color: #202020;">Macular Cube 512 x 128 Combo: 128 horizontal scan lines comprised of 512 A-scans</span></li>
<li><span style="color: #202020;">5 Line Raster: 4096 A-scans per B-Scan (adjustable length, spacing and orientation)</span></li>
</ul>
<p><span style="color: #202020;">Zeiss Cirrus HD-OCT 4000 System Focus Adjustment Range</span></p>
<ul>
<li><span style="color: #202020;">−20D to 20D (diopters)</span></li>
</ul>
<p><span style="color: #202020;">Fixation</span></p>
<ul>
<li><span style="color: #202020;">Internal and external</span></li>
</ul>
<p><span style="color: #202020;">Computer</span></p>
<ul>
<li><span style="color: #202020;">Windows 7 OS</span></li>
<li>Internal storage: &gt; 80,000 scans</li>
<li><span style="color: #202020;">CD-RW, DVD-ROM drive</span></li>
<li><span style="color: #202020;">Integrated 15&#8243; color flat panel display</span></li>
</ul>
<p><span style="color: #202020;">Pupil Size Requirement</span></p>
<ul>
<li><span style="color: #202020;">≤ 2.0 mm (≥ 3.0 mm optimal for LSO)</span></li>
</ul>
<p><span style="color: #202020;">Dimensions/Weight (Instrument Only)</span></p>
<ul>
<li><span style="color: #202020;">25.6 L x 17.3 W x 20.9 H (in); 65 L x 44 W x 53 H (cm)</span></li>
<li><span style="color: #202020;">83 lbs; 37.6 kg</span></li>
</ul>
<p><span style="color: #202020;">Electrical</span></p>
<ul>
<li><span style="color: #202020;">100-120V~, 50/60Hz, 5A 220-240V~, 50/60Hz, 2.5A</span></li>
</ul>
<p>The post <a href="https://www.multihealthbeauty.com/product/zeiss-cirrus-hd-oct-4000-system/">Zeiss Cirrus HD-OCT 4000 System</a> appeared first on <a href="https://www.multihealthbeauty.com">MULTIHEALTH BEAUTY</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.multihealthbeauty.com/product/zeiss-cirrus-hd-oct-4000-system/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">5736</post-id>	</item>
	</channel>
</rss>